Specification
Item | Model | Model |
---|---|---|
Spindle Model | GDL80-20-24Z-1.5 | GDL80-20-24Z-2.2 |
Dimension L*H [mm] | 286 * 108 | 286 * 108 |
Max. Speed | 24000 rpm | 24000 rpm |
Rated Power [kW] | 1.5 | 2.2 |
Max. Voltage [V] | 220 | 220 |
Max. Current | 5.8 | 6.8 |
Max. Frequency | 800Hz | 800Hz |
Number of Pole | 4 | 4 |
Bearings | 2*HY6005C P4 &1*SM6004C P4 | 2*HY6005C P4 &1*SM6004C P4 |
Collet | ER16 / ER20* | ER16 / ER20* |
Tool Holder | ISO 20 | ISO 20 |
Max. Taper run out | 3 µm | 3 µm |
Cooling Type | Water | Water |
Cooling Flow | 3 -6 l/m | 3 - 6 l/m |
Lubricate | Grease | Grease |
Tool Change Mechanism | Pneumatic | Pneumatic |
Weight | 8 kg | 8 kg |
Price [without Tax] | 1790.00 € | 1850.00 € |
Pictures, dimensions,table data and technical drawings of this product are made with reasonable care and liability is excluded for the accuracy and correctness of this data
*ISO 20 tool holder can be with ER16 Collet (tool capacity 0.5-10mm) or ER20 Collet (tool capacity 1-13mm)
Connectors - Input / Output
Spindles required the use of a VFD (Variable Frequency Drive) to function. These VFDs are also called spindle inverters. The VFD takes the power from the wall and creates a frequency with voltage and current to spin the spindle. The frequency can be controlled to control the RPM of the spindle
NOTE: Do not directly plug it into electricity power, Spindle can be connected only to Frequency Inverter!
Connector | Description | Drawing |
---|---|---|
1 | Power line: Three-color lines connected with UVW phases. | ![]() |
1 | * Temperature control line - Thermistor: 110°C thermistor two-wire connected (brown / brown) with the temperature-controler unit. |
|
1 | Ground: Yellow and green wires for Ground. | |
2 | Cooling water inlet: Max. 0,8 Bar (8m pump head), 8/6mm hose | |
3 | Air Inlet: dust removal, pressure 2-3 Bar (6/4 hoses) | |
4 | ** Two proximity switches: NPN for tool-loading and tool-unloading (normally open) N.O. | |
5 | Air seal: pressure 1-2 Bar (4/2 hoses) | |
6 | Cooling water outlet: 8/6mm hose | |
7 | Air inlet for Tool Change pneumatic cylinder, 6-7 Bar (6/4 hoses) |
Do not attempt to wire your VFD or spindle on your own. Consult with a professional electrician before following the diagram!
* PTC single-core Thermistor parameter |
||
-20-25ºC | ≤300Ω | |
≤90ºC | ≤750Ω | |
105ºC | ≤1650Ω | |
110ºC | Rated operating themperature | |
115ºC | ≥3990Ω | |
≥125ºC | ≥12KΩ | |
≤160ºC | Maximum storage temperature |
** Wiring method of the proximity switch: Brown wire connect to +24VDC, blue wire connect to 0VDC and black wire is a signal (you can use this signal wire to detect clamping mechanism position
Caution: